This instruction manual is for the Olympus Microscope Digital Camera Model DP71. To ensure the safety, obtain optimum performance and familiarize yourself fully with the use of this camera, we recommend that you study this manual thoroughly before operating the camera. For image operations including recording, editing and saving, please refer to the Online Help […]
Search Results for microscope camera instructions
Olympus DP71 Microscope Digital Camera Instructions
October 27th, 2009 · No Comments
Tags: Digital Cameras
Setting up the Nikon TE2000-E microscope for DIC Imaging
October 6th, 2009 · No Comments
1. Turn the microscope power (A) on at the back of the scope
2. Turn the bright field light source on
3. Make sure the DIA lamp is ON on the microscope controller box (B)
4. Make sure the light path is directed to they eyepieces on the controller box (B)
5. Light intensity can be adjusted with up/down […]
Tags: Peripheral
Keeler Slit Lamp Instructions
September 30th, 2009 · No Comments
Keeler Slit Lamps are instruments designed to give a very high level of performance. In order to ensure you gain the maximum benefits from your Keeler Slit Lamp we suggest that you read this instruction manual carefully before assembly or use. Please be sure to check all warning or rating labels on your Slit […]
Tags: Others
UniClamp Instructions
September 30th, 2009 · No Comments
Here we’ll demonstrate, using our Nikon CP 950. The purpose of the photo is to show the Camera Tripod Mount Platform attached, and alignment of the Center Line of the UniClamp with respect to the center line of the Camera Lens. With this type of camera, the lens is fixed (doesn’t move in or out) […]
Tags: Others
Using The Nikon CoolPix 995 For Microscopic Photography
September 28th, 2009 · No Comments
The document will serve as a guide for setting up the Nikon 995 camera for microscopic photography.
Attaching the Camera to the Microscope
1. Remove the right eyepiece from the microscope by loosening the small
Allen screw located around the bottom ring of the eyepiece using the supplied Allen wrench. Note: turning the small Allen screw counterclockwise loosens […]
Tags: Digital Cameras
Nikon Eclipse E800 Instructions
September 26th, 2009 · No Comments
he ImageCORE’s Nikon Eclipse E-800 is set up as a high-resolution fluorescence acquisition microscope. The Eclipse is coupled to a 12-bit QImaging Retiga 1300i digital capture camera. Use of this acquisition system should be limited to those investigators that have observed their samples previously on lower resolution systems and require the image quality afforded by […]
Tags: Peripheral
Nikon Optiphot Instructions
September 25th, 2009 · No Comments
The ImageCORE’s Nikon Optiphot-2 is set up as a digital fluorescence acquisition microscope. The Eclipse is coupled to a 12-bit Roper Coolsnap CF digital capture camera. This system should be used to observe and record images prior to use of other, higher resolution, ImageCORE resources.
Tags: Peripheral